Pitfalls in Diagnosing PFO: Characteristics of False-Negative Contrast Injections during Transesophageal Echocardiography in Patients with Patent Foramen Ovales
Pitfalls in Diagnosing PFO: Characteristics of False-Negative Contrast Injections during Transesophageal Echocardiography in Patients with Patent Foramen Ovales
复制标题
DOI:
10.1016/j.echo.2010.08.004
复制
发表时间:
2010-11-01
影响因子:
6.5
通讯作者:
Dellborg, Mikael
中科院分区:
文献类型:
--
作者:
Johansson, Magnus C.;Eriksson, Peter;Dellborg, Mikael
Background: Contrast injections during transesophageal echocardiography for patent foramen ovale (PFO) detection may be false negative. The characteristics of false-negative injections were studied retrospectively.Methods: Contrast transesophageal echocardiography was analyzed for the presence or absence of two characteristics: leftward bulging of the interatrial septum and dense contrast filling of the region of the right atrium adjacent to the interatrial septum.Results: Two hundred forty-seven injections were administered to 14 patients with PFOs, and 130 (53%) were false negative. The absence of either characteristic during a single injection resulted in low sensitivity for PFO detection of 7%. When the two characteristics were present at the same time, the sensitivity for PFO detection after a single injection was as high as 95%.Conclusions: The simultaneous presence of both leftward bulging of the interatrial septum and dense contrast filling of the region in the right atrium, adjacent to the interatrial septum, is a prerequisite for PFO detection, and if either characteristic is missing, the injection is inconclusive. (J Am Soc Echocardiogr 2010; 23: 1136-42.)