Progress on the MICE Tracker Solenoids
Progress on the MICE Tracker Solenoids
复制标题
MICE 跟踪器电磁阀的进展
DOI:
--
复制
发表时间:
2008
影响因子:
1.8
通讯作者:
S. Virostek
中科院分区:
文献类型:
--
作者:
M. A. Green;S. Virostek
The first magnets for the muon ionization cooling experiment will be the tracker solenoids that form the ends of the MICE cooling channel. The primary purpose of the tracker solenoids is to provide a uniform 4 T field (to better than plusmn0.3 percent over a volume that is 1 meter long and 0.3 meters in diameter) spectrometer magnet field for the scintillating fiber detectors that are used to analyse the muons in the channel before and after ionization cooling. A secondary purpose for the tracker magnet is the matching of the muon beam between the rest of the MICE cooling channel and the uniform field spectrometer magnet. The tracker solenoid is powered by three 300 amp power supplies. Additional tuning of the spectrometer is provided by a pair of 50 amp power supplies across the spectrometer magnet end coils. The tracker magnet will be cooled using a pair of 4 K pulse tube coolers that each provide 1.5 W of cooling at 4.2 K. Final design and construction of the tracker solenoids began during the summer of 2006. This report describes the progress made on the construction of the tracker solenoids.