3-D finite element analysis of current distribution in HTS power cable taking account of E-J power law characteristic

3-D finite element analysis of current distribution in HTS power cable taking account of E-J power law characteristic
复制标题

考虑E-J幂律特性的高温超导电缆电流分布三维有限元分析

DOI:
10.1109/tmag.2004.825020
复制
发表时间:
2004
影响因子:
2.1
通讯作者:
K. Ueda
K. Ueda
中科院分区:
工程技术4区
文献类型:
--
作者:
D. Miyagi;T. Wakatsuki;N. Takahashi;S. Torii;K. Ueda

文献摘要

被引文献

相似文献

利用各向异性电导率和考虑E-J幂定律特性的三维有限元方法,研究了高温超导(HTS)电力电缆电流分布的分析方法。给出了电缆中详细的电流分布,并考察了高温超导屏蔽的屏蔽效果。
A method for analyzing the current distribution in high-T/sub c/ superconducting (HTS) power cable is examined by the aid of the novel use of anisotropic conductivity and three-dimensional finite element method in consideration of the E-J power law characteristic. The detailed current distribution in the cable is illustrated and the shielding effect of HTS shield is also examined.