Conceptual design of high resolution and reliable density measurement system on helical reactor FFHR-d1 and demonstration on LHD
Conceptual design of high resolution and reliable density measurement system on helical reactor FFHR-d1 and demonstration on LHD
复制标题
DOI:
10.1088/0029-5515/55/9/093032
复制
发表时间:
2015-09
期刊:
影响因子:
3.3
通讯作者:
T. Akiyama;R. Yasuhara;T. Tanaka;M. Isobe;R. Sakamoto;T. Goto;K. Kawahata;K. Nakayama;S. Okajima;A. Sagara
中科院分区:
文献类型:
--
作者:
T. Akiyama;R. Yasuhara;T. Tanaka;M. Isobe;R. Sakamoto;T. Goto;K. Kawahata;K. Nakayama;S. Okajima;A. Sagara
This paper describes a conceptual design of the density measurement system on the helical reactor FFHR-d1 based upon its quantitative operation scenario. The density measurement is necessary to satisfy the reactor design, and to have a high density resolution of the order of 1017 m−3 with a time resolution of 10 ms. High reliability that avoids measurement failures is also necessary. A combined system of ‘a dispersion interferometer’ and a polarimeter is designed and a prototype of the dispersion interferometer with an Nd:YAG laser is tested. The dispersion interferometer with a CO2 laser is also installed on LHD, which can realize a demo relevant density plasma. The prototypes demonstrate the feasibility on a demo reactor.