Measurements of wavelength-dependent double photoelectron emission from single photons in VUV-sensitive photomultiplier tubes
Measurements of wavelength-dependent double photoelectron emission from single photons in VUV-sensitive photomultiplier tubes
复制标题
真空紫外敏感光电倍增管中单光子的波长相关双光电子发射测量
DOI:
10.1088/1748-0221/10/09/p09010
复制
发表时间:
2015
影响因子:
1.3
通讯作者:
R. Gaitskell
中科院分区:
文献类型:
--
作者:
C. Faham;V. Gehman;A. Currie;A. Dobi;P. Sorensen;R. Gaitskell
Measurements of double photoelectron emission (DPE) probabilities as a function of wavelength are reported for Hamamatsu R8778, R8520, and R11410 VUV-sensitive photomultiplier tubes (PMTs). In DPE, a single photon strikes the PMT photocathode and produces two photoelectrons instead of a single one. It was found that the fraction of detected photons that result in DPE emission is a function of the incident photon wavelength, and manifests itself below ∼250 nm. For the xenon scintillation wavelength of 175 nm, a DPE probability of 18–24% was measured depending on the tube and measurement method. This wavelength-dependent single photon response has implications for the energy calibration and photon counting of current and future liquid xenon detectors such as LUX, LZ, XENON100/1T, Panda-X and XMASS.