Development of dimethyl sulfoxide biosensor using a mediator immobilized enzyme electrode

Development of dimethyl sulfoxide biosensor using a mediator immobilized enzyme electrode
复制标题

DOI:
10.1039/b212917e
复制
发表时间:
2003-01-01
期刊:
影响因子:
4.2
通讯作者:
Okubo, A
Okubo, A
中科院分区:
化学2区
文献类型:
--
作者:
Cheng, HC;Abo, M;Okubo, A

文献摘要

被引文献

相似文献

以二甲基亚砜还原酶(DMSO- r)为载体构建了固定化二甲基亚砜(DMSO)传感器。以甲基紫素(MV)为介体,用Nafion聚合物固定在玻碳(GC)电极上。改性气相色谱电极上的透析膜保留了球形红杆菌反硝化菌的DMSO-R。观察了DMSO对电流信号的响应。DMSO的校准曲线线性范围为0 ~ 600 μ m。在200 muM DMSO条件下,反应时间在100 s以内,相对标准偏差为4% (n = 4)。为了消除样品中氧气产生的背景噪声,葡萄糖氧化酶-过氧化氢酶保留DMSO传感器也进行了检测。
A mediator immobilized dimethyl sulfoxide (DMSO) sensor using DMSO reductase (DMSO-R) was constructed. Methyl viologen (MV) was used as a mediator and immobilized on a glassy carbon (GC) electrode with Nafion polymer. DMSO-R from Rhodobacter sphaeroides f. sp. denitrificans was retained by a dialysis film on the modified GC electrode. The amperometric signal in response to DMSO was observed. The linear range of the calibration curve for DMSO was between 0 and 600 muM. The response time was within 100 s and the relative standard deviation was 4% at 200 muM DMSO (n = 4). To eliminate the background noise derived from oxygen in samples, the glucose oxidase-catalase retained DMSO sensor was also examined.