Surgical management of hypothenar and thenar hammer syndromes: A retrospective study of 31 instances in 28 patients
Surgical management of hypothenar and thenar hammer syndromes: A retrospective study of 31 instances in 28 patients
复制标题
DOI:
10.1016/j.jhsb.2005.02.013
复制
发表时间:
2005-08-01
期刊:
影响因子:
--
通讯作者:
Houpt, P
中科院分区:
文献类型:
--
作者:
Dethmers, RSM;Houpt, P
This retrospective study assessed the results of treatment of 29 cases of hypothenar hammer syndrome and two cases of thenar hammer syndrome. Three hands were symptom free, 15 were improved, 11 were unchanged and two were worse at a mean follow-up of 43 (range 4-60) months. Follow-up colour-coded Duplex sonography of revascularizations (n = 27) revealed 13 patent, five occluded and one partially thrombosed grafts, seven grafts with aneurysmal dilatations and one coiled graft. Colour-coded Duplex sonography results after venous interposition graft combined with endoscopic thoracic sympathectomy were no better than venous interposition graft alone. All three arterial interposition grafts and two end-to-end-reconstructions were patent. The Duplex outcomes of the revascularizations did not correspond well with the clinical outcomes. Endoscopic thoracic sympathectomy was associated with a high rate of inconvenient side effects.