Comparison of clinicians and an artificial neural network regarding accuracy and certainty in performance of visual field assessment for the diagnosis of glaucoma
Comparison of clinicians and an artificial neural network regarding accuracy and certainty in performance of visual field assessment for the diagnosis of glaucoma
复制标题
DOI:
10.1111/j.1755-3768.2012.02435.x
复制
发表时间:
2013-08-01
影响因子:
3.4
通讯作者:
Bengtsson, Boel
中科院分区:
文献类型:
--
作者:
Andersson, Sabina;Heijl, Anders;Bengtsson, Boel
. Purpose: To compare clinicians and a trained artificial neural network (ANN) regarding accuracy and certainty of assessment of visual fields for the diagnosis of glaucoma. Methods: Thirty physicians with different levels of knowledge and experience in glaucoma management assessed 30-2 SITA Standard visual field printouts that included full Statpac information from 99 patients with glaucomatous optic neuropathy and 66 healthy subjects. Glaucomatous eyes with perimetric mean deviation values worsethan -10dB were not eligible. The fields were graded on a scale of 1-10, where 1 indicated healthy with absolute certaintyand 10 signified glaucoma; 5.5 was the cut-off between healthy and glaucoma. The same fields were classified by a previously trained ANN. The ANN output was transformed into a linear scale that matched the scale used in the subjective assessments. Classification certainty was assessed using a classification error score. Results: Among the physicians, sensitivity ranged from 61% to 96% (mean 83%) and specificity from 59% to 100% (mean 90%). Our ANN achieved 93% sensitivity and 91% specificity, and it was significantly more sensitive than the physicians (p