Note: Effect of hot liner in producing 40,48Ca beam from RIKEN 18-GHz electron cyclotron resonance ion source.
Note: Effect of hot liner in producing 40,48Ca beam from RIKEN 18-GHz electron cyclotron resonance ion source.
复制标题
注:热衬管对从 RIKEN 18 GHz 电子回旋共振离子源产生 40,48Ca 束流的影响。
DOI:
10.1063/1.4906595
复制
发表时间:
2015
期刊:
影响因子:
--
通讯作者:
T. Nakagawa
中科院分区:
文献类型:
--
作者:
K. Ozeki;Y. Higurashi;M. Kidera;T. Nakagawa
In order to produce a high-intensity and stable (48)Ca beam from the RIKEN 18-GHz electron cyclotron resonance ion source, we have begun testing the production of a calcium beam using a micro-oven. To minimize the consumption rate of the material ((48)Ca), we introduced the "hot liner" method and investigated the effect of the liner on the material consumption rate. The micro-oven was first used to produce the (48)Ca beam for experiments in the RIKEN radioisotope beam factory, and a stable beam could be supplied for a long time with low consumption rate.