Development of Active Gas-Gap Heat Switch for Double-Stage Adiabatic Demagnetization Refrigerators
Development of Active Gas-Gap Heat Switch for Double-Stage Adiabatic Demagnetization Refrigerators
复制标题
双级绝热退磁制冷机主动气隙热开关的研制
DOI:
10.1007/s10909-012-0594-7
复制
发表时间:
2012
影响因子:
2
通讯作者:
T.Oshima
中科院分区:
文献类型:
--
作者:
Y.Ishisaki;K.Henmi;H.Akamatsu;T.Enoki;T.Ohashi;A.Hoshino;K.Shinozaki;H.Matsuo;N.Okada;T.Oshima
We designed and fabricated an active gas-gap heat switch (AGGHS), which ON/OFF the heat conduction between the 1st stage (0.05–2 K) and the 2nd stage (1–4 K) of a double-stage adiabatic demagnetization refrigerator (DADR). Our design geometrically separates two components which dominates the ON or OFF performance, and achieved heat conductivity of 6 mW/K (ON) or 4 μW/K (OFF) at 2 K. The ON/OFF is controlled by a heater attached to the charcoal box to adsorb/deadsorb4He gas inside. We introduced the AGGHS to the DADR and successfully cooled the detector stage down to 60 mK, working properly more than a year.