Evaluation of complete denture occlusal contacts using pressure-sensitive sheets.
Evaluation of complete denture occlusal contacts using pressure-sensitive sheets.
复制标题
使用压敏片评估全口义齿咬合接触。
DOI:
--
复制
发表时间:
1997
影响因子:
2.3
通讯作者:
M. Nagao
中科院分区:
文献类型:
--
作者:
Tetsuya Suzuki;H. Kumagai;Tatsutomi Watanabe;T. Uchida;M. Nagao
This study evaluated the efficacy of a new occlusal analysis system (Dental Prescale System) composed of pressure-sensitive sheets and a computer for analysis for complete denture wearers. In the laboratory portion of the study, the system registered values that were greater than the actual applied loads (mean 6.3 +/- 10.6 N). Clinical measurements of five parameters related to the analysis of occlusion were made using two groups: 50 wearers of nonadjusted complete dentures and 50 wearers of adjusted prostheses. An error discrimination rate of 16% resulted between the two groups. This system is capable of measuring occlusal pressure at every contact point and can be considered a useful method for occlusal analysis and patient screening.