Monitoring of (reactive) ion etching (RIE) with reflectance anisotropy spectroscopy (RAS) equipment
Monitoring of (reactive) ion etching (RIE) with reflectance anisotropy spectroscopy (RAS) equipment
复制标题
DOI:
10.1016/j.apsusc.2014.12.038
复制
发表时间:
2015-02-15
影响因子:
6.7
通讯作者:
Kopnarsk, Michael
中科院分区:
文献类型:
--
作者:
Barzen, Lars;Richter, Johannes;Kopnarsk, Michael
Experimental results on the application of reflectance anisotropy spectroscopy (RAS) to the monitoring of (reactive) ion etching of monocrystalline semiconductor samples are described. To show the potential of this technique RAS signals collected during etching of GaAs/AlxGa1-xAs multilayer samples are compared to RAS data obtained before during molecular-beam epitaxial (MBE) growth of these very samples. A change of the RIE-RAS spectrum can be attributed to a change of material composition. And the current etch depth can be monitored with an accuracy at least down to several tens of nanometers -f. e. by recording the average reflected intensity. (C) 2014 Elsevier B. V. All rights reserved.