Individualized recording chambers for non-human primate neurophysiology.
Individualized recording chambers for non-human primate neurophysiology.
复制标题
DOI:
10.1016/j.jneumeth.2012.03.014
复制
发表时间:
2012-05-30
影响因子:
3
通讯作者:
Helms Tillery SI
中科院分区:
文献类型:
--
作者:
McAndrew RM;Lingo VanGilder JL;Naufel SN;Helms Tillery SI
While neural recording chambers for non-human primates can be purchased commercially, these generic chambers do not contour to the animal’s skull. In order to seal gaps, a cap of dental acrylic (methyl methacrylate) is often applied around the chamber. There are multiple disadvantages associated with this method. Applying acrylic delays and further complicates surgical procedure, and overheating during the curing process can cause damage to the bone. Post-surgery, acrylic margins can give rise to bacterial growth and infection. Here we describe a method to develop custom implants which conform to the individual’s skull, thereby eliminating the need for acrylic. This method shortens surgery time and significantly improves the hygiene of chamber margins.