Influence of Air Pollution Control Devices on the Polycyclic Aromatic Hydrocarbon Distribution in Flue Gas from an Ultralow-Emission Coal-Fired Power Plant
Influence of Air Pollution Control Devices on the Polycyclic Aromatic Hydrocarbon Distribution in Flue Gas from an Ultralow-Emission Coal-Fired Power Plant
复制标题
DOI:
10.1021/acs.energyfuels.6b01381
复制
发表时间:
2016-10
期刊:
影响因子:
5.3
通讯作者:
Jingwei Li;Xiaodong Li;Min Li;Shengyong Lu;Jian-hua Yan;Xie Wei-yang;Li Chunhong;Zhifu Qi
中科院分区:
文献类型:
--
作者:
Jingwei Li;Xiaodong Li;Min Li;Shengyong Lu;Jian-hua Yan;Xie Wei-yang;Li Chunhong;Zhifu Qi
Coal-fired power plants are known to release a large quantity of polycyclic aromatic hydrocarbons (PAHs) and particulate matter. Some power plants have been upgraded with flue gas purification equipment to achieve ultralow emission. A coal-fired unit with ultralow emission was selected to investigate the influence of gas purification equipment on the PAH distribution in flue gas. The total concentration of the 16 PAHs at the inlet of the wet flue gas desulfurization (WFGD) system was 6.340 μg/m3, and naphthalene (Nap) was shown to be the major PAH compound. The total concentration of the 16 PAHs at the outlet of the wet electrostatic precipitator (WESP) was 0.870 μg/m3, and the 5-ring and 6-ring PAHs were the major PAH compounds. The WFGD system could partially reduce the concentration of PAHs in the flue gas. The WESP eliminated most of the Nap and a portion of the gas-phase PAHs, whereas the concentrations of some 5-ring and 6-ring PAHs in the particulate phase increased as the flue gas passed through t...