在这封信中,肥厚型心肌病(HCM)的自动检测算法。特别令人感兴趣的是,该算法能够区分HCM受试者和健康志愿者从一个单一的铅ECG数据集。疑似HCM受试者通过与HCM相关的主要临床异常来识别:左心室肥大(LVH)。总共研究了n= 43个人类受试者ECG数据集:n= 21个健康志愿者和n = 22个LVH患者。对于相应的ECG参数,发现p值0.01和0.04的显著差异,即,S波振幅和ST段,区分LVH患者和健康志愿者。
In this letter, an automatic detection algorithm for hypertrophic cardiomyopathy (HCM) is presented. Of particular interest is the algorithm's ability to differentiate HCM subjects and healthy volunteers from a single lead ECG dataset. Suspected HCM subjects are identified by the primary clinical abnormality associated with HCM: left ventricular hypertrophy (LVH). In total,n= 43 human subjects ECG datasets are investigated:n= 21 healthy volunteers andn= 22 LVH patients. Significant differences ofp-value 0.01 and 0.04 were found for the respective ECG parameters, i.e., S-wave amplitude and ST-segment, when differentiating between the LVH patients and healthy human volunteers.