Weighting Factor-Less Sequential Predictive Control of LC-Filtered Voltage Source Inverters

Weighting Factor-Less Sequential Predictive Control of LC-Filtered Voltage Source Inverters
复制标题

DOI:
10.1155/2022/5190885
复制
发表时间:
2022-04
影响因子:
2.3
通讯作者:
Changming Zheng;Zheng Gong;Rongwu Zhu
Changming Zheng;Zheng Gong;Rongwu Zhu
中科院分区:
工程技术4区
文献类型:
--
作者:
Changming Zheng;Zheng Gong;Rongwu Zhu

文献摘要

相似文献

To eliminate the weighting factor tuning effort of typical finite-set model predictive control (FS-MPC), this paper proposes a weighting factor-less sequential model predictive control (SMPC) scheme for LC-filtered voltage source inverters. Two independent cost functions for minimizing capacitor-voltage and inductor-current tracking errors are deployed in a cascaded structure, eliminating the weighting factor. First, the optimal cascade order of the cost function is selected by the internal relationship of two control variables. Then, a graphical method is proposed to determine the optimal number of candidate voltage vectors selected from the first cost function. Moreover, to realize the strict current limitation, the current-constraint term is proved to be included in the voltage-related cost function. Another attractive feature of the proposed SMPC is that a smoother inductor-current starting response can be obtained compared to typical FS-MPC. Simulation and experimental results verify the feasibility of the presented approach.