Accuracy of the Welch Allyn SureSight for measurement of magnitude of astigmatism in 3- to 7-year-old children.

Accuracy of the Welch Allyn SureSight for measurement of magnitude of astigmatism in 3- to 7-year-old children.
复制标题

DOI:
10.1016/j.jaapos.2009.08.013
复制
发表时间:
2009-10
期刊:
影响因子:
1.6
通讯作者:
Garvey, Katherine A.
Garvey, Katherine A.
中科院分区:
医学4区
文献类型:
--
作者:
Harvey, Erin M.;Dobson, Velma;Miller, Joseph M.;Clifford-Donaldson, Candice E.;Green, Tina K.;Messer, Dawn H.;Garvey, Katherine A.

文献摘要

参考文献

被引文献

相似文献

在高度散光患病率较高的美国土著人群儿童中,评价Welch Allyn SureSight在非睫状肌麻痹散光测量中与睫状肌麻痹Retinomax K+自动验光仪散光测量相比的准确性。报告了825例3至7岁儿童的数据,无眼部异常。每名儿童均接受了右眼散光的Retinomax K+睫状肌麻痹测量,置信度≥8,并尝试3次获得右眼的SureSight测量。SureSight测量成功率在不同年龄或测量置信度之间无显著差异(<6 vs ≥6)。96%的儿童至少有1次测量(任何置信度),89%的儿童至少有1次测量的置信度在制造商的推荐值(≥6)。总体而言,SureSight倾向于高估散光。如果SureSight测量具有任何屈光值(0.00 D至3.00 D),则可能存在2.00 D或更小的散光。如果SureSight显示散光超出仪器的屈光度范围(>3.00 D),Retinomax K+测量表明157例中有136例(86.6%)存在>2.00 D的散光。在SureSight无法提供阅读的合作儿童中,34名儿童中有32名(94%)散光>3.00 D。SureSight不提供散光量的准确定量测量。然而,它确实可以将散光量准确分类为≤2.00 D、>2.00 D或>3.00 D,并且在幼儿中具有较高的测量成功率。
To evaluate the accuracy of the Welch Allyn SureSight in noncycloplegic measurements of astigmatism as compared to cycloplegic Retinomax K+ autorefractor measurements of astigmatism in children from a Native American population with a high prevalence of high astigmatism. Data are reported for 825 3- to 7-year-old children with no ocular abnormalities. Each child had a Retinomax K+ cycloplegic measurement of right eye astigmatism with a confidence rating ≥8 and 3 attempts to obtain a SureSight measurement on the right eye. SureSight measurement success rates did not differ significantly across age or measurement confidence rating (<6 vs ≥6). Ninety-six percent of children had at least 1 measurement (any confidence), and 89% had at least 1 measurement with confidence at the manufacturer's recommended value (≥6). Overall, the SureSight tended to overestimate astigmatism. If the SureSight measurement had any dioptric value (0.00 D to 3.00 D), astigmatism of 2.00 D or less was likely to be present. If the SureSight showed astigmatism beyond the instrument's dioptric range (>3.00 D), Retinomax K+ measurements indicated that >2.00 D of astigmatism was present in 136 of 157 (86.6%). In cooperative children for whom the SureSight would not give a reading, 32 of 34 (94%) had >3.00 D of astigmatism. The SureSight does not provide an accurate, quantitative measure of amount of astigmatism. However, it does allow accurate categorization of amount of astigmatism as ≤2.00 D, >2.00 D, or >3.00 D, and it has high measurement success rate in young children.
DOI: 10.1097/00006324-199405000-00002
发表时间: 1994-05-01
影响因子: 1.4
作者:
CHAN, OYC;EDWARDS, M
通讯作者: EDWARDS, M
DOI: 10.1016/s1091-8531(99)70062-5
发表时间: 1999-06-01
期刊: JOURNAL OF AAPOS
影响因子: 1.6
作者:
Miller, JM;Harvey, EM;Dobson, V
通讯作者: Dobson, V
DOI: 10.1097/01.opx.0000214333.84822.71
发表时间: 2006-04-01
影响因子: 1.4
作者:
Harvey, EM;Dobson, V;Miller, JM
通讯作者: Miller, JM
DOI: 10.1097/00006324-200401000-00010
发表时间: 2004-01-01
影响因子: 1.4
作者:
Zhao, JL;Mao, J;Ellwein, LB
通讯作者: Ellwein, LB
DOI: 10.1016/s0275-5408(00)00048-x
发表时间: 2001-03-01
影响因子: 2.9
作者:
Chat, SWS;Edwards, MH
通讯作者: Edwards, MH