Meter-scale multi-loop capillary heat pipe
Meter-scale multi-loop capillary heat pipe
复制标题
DOI:
10.1016/j.applthermaleng.2018.05.116
复制
发表时间:
2018-08
影响因子:
6.4
通讯作者:
S. Okazaki;H. Fuke;H. Ogawa;Y. Miyazaki;Katsumasa Takahashi;N. Yamada
中科院分区:
文献类型:
--
作者:
S. Okazaki;H. Fuke;H. Ogawa;Y. Miyazaki;Katsumasa Takahashi;N. Yamada
In this study, a newly proposed heat pipe system was investigated to transfer heat from a vertical heated plate to a vertical cooled plate arranged in parallel. The heat pipe system comprises 32 loops connected in series and a reservoir. Each square-shaped loop (with a side length of 2 m) comprises a capillary tube with an inner diameter of 1.0 mm without any internal wick. The system’s overall thermal performance was investigated at room temperature using R410A as the working fluid. Temperatures, pressures, and reservoir weight were monitored, and thereby confirming that the system transfers heat up to several hundred watts by a passive two-phase flow. Numerical simulations with a simple model were consistent with the data and verified that the saturated pressure of the system is controlled by the reservoir temperature independent of the amount of heat load.