Development and validation of a dried blood spot assay for the quantification of ribavirin using liquid chromatography coupled to mass spectrometry.

Development and validation of a dried blood spot assay for the quantification of ribavirin using liquid chromatography coupled to mass spectrometry.
复制标题

DOI:
10.1016/j.jchromb.2013.10.035
复制
发表时间:
2014-01-01
影响因子:
3
通讯作者:
Kiser, Jennifer J.
Kiser, Jennifer J.
中科院分区:
医学3区
文献类型:
--
作者:
Jimmerson, Leah C.;Zheng, Jia-Hua;Bushman, Lane R.;MacBrayne, Christine E.;Anderson, Peter L.;Kiser, Jennifer J.

文献摘要

参考文献

被引文献

相似文献

用于测量药物的高效、廉价和灵敏的测定对于药代动力学和药效学(PK-PD)分析是感兴趣的。干血斑(DBS)是一种独特的生物分析基质,具有满足测量许多分析物的这种兴趣的潜力。在这里,我们描述了一个反相高效液相色谱(LC),串联质谱(MS/MS)测定利巴韦林(RBV)在DBS的开发和验证。使用同位素标记的内标物在甲醇中提取来自点样和干燥全血的3 mm穿孔物,用于LC-MS/MS分析。在0.05 μg/mL至10.0 μg/mL范围内进行验证,结果表明该方法具有精密度(变异系数≤ 15%)和准确度(在对照品的±15%范围内)。对于20- 54%的红细胞压积范围、中心与边缘冲孔以及10-60 μL的斑点体积,符合这些验收标准。RBV在室温和−20°C下以及三个冻融循环中可稳定长达140天。DBS与血浆中RBV的相关性产生r2 ≥ 0.98,表明DBS可用作人类受试者PK-PD研究中血浆的替代品。
Efficient, inexpensive and sensitive assays for the measurement of drugs are of interest for pharmacokinetic and pharmacodynamics (PK-PD) analysis. Dried blood spots (DBS) are a unique bioanaltyical matrix with the potential to fulfill this interest for the measurement of numerous analytes. Here we describe the development and validation of a reversed-phase high performance liquid chromatographic (LC), tandem mass spectrometry (MS/MS) assay for the determination of ribavirin (RBV) in DBS. A 3mm punch from spotted and dried whole blood was extracted in methanol utilizing isotopically labeled internal standard for LC-MS/MS analysis. Validation was performed over a range of 0.05 μg/mL to 10.0 μg/mL and the method was shown to be precise (coefficient of variation ≤ 15%) and accurate (within ±15% of control). These acceptance criteria were met for hematocrit ranges of 20-54%, for center versus edge punches and for spot volumes from 10-60 μL. RBV was stable for up to 140 days at room temperature and −20°C as well as for three freeze/thaw cycles. Correlation of RBV in DBS versus in plasma yielded r2 ≥ 0.98 demonstrating that DBS can be used as an alternative to plasma for PK-PD studies in human subjects.
DOI: 10.1016/j.cca.2006.04.013
发表时间: 2006-11-01
影响因子: 5
作者:
Holub, Margareta;Tuschl, Karin;Bodamer, Olaf A.
通讯作者: Bodamer, Olaf A.
DOI: 10.1002/rcm.4990
发表时间: 2011-05-15
影响因子: 2
作者:
Liu, Guowen;Snapp, Heidi M.;Ji, Qin C.
通讯作者: Ji, Qin C.
DOI: 10.1128/aac.00831-06
发表时间: 2007-06-01
影响因子: 4.9
作者:
Durand-Gasselin, Lucie;Da Silva, David;Grassi, Jacques
通讯作者: Grassi, Jacques
DOI: 10.1021/ac020361s
发表时间: 2003-07-01
影响因子: 7.4
作者:
Matuszewski, BK;Constanzer, ML;Chavez-Eng, CM
通讯作者: Chavez-Eng, CM
DOI: 10.1089/aid.2012.0089
发表时间: 2013-02-01
影响因子: 1.5
作者:
Castillo-Mancilla, Jose R.;Zheng, Jia-Hua;Anderson, Peter L.
通讯作者: Anderson, Peter L.