Causes of weld porosity in electroformed nickel
Causes of weld porosity in electroformed nickel
复制标题
DOI:
--
复制
发表时间:
1979-12
期刊:
影响因子:
--
通讯作者:
J. Brooks;J. Dini;H. R. Johnson
中科院分区:
文献类型:
--
作者:
J. Brooks;J. Dini;H. R. Johnson
Information provided by thermogravimetric analysis was coupled with studies of gas tungsten arc welds to determine the causes of weld porosity in electroformed nickel. When both C and O did not exceed approx. 40 ppM and N was approx. 80 ppM or less in the deposit, no porosity was observed following welding. Increasing the C and O to 60 to 70 ppM and N to 100 ppM resulted in significant porosity in welded samples. Thermogravimetric analysis indicated that the porosity could result from N/sub 2/ and/or C plus O combining to form CO and CO/sub 2/. There were also indications that SO/sub 2/ contributed to the porosity.