Mechanical behavior of circular and square concrete filled steel tube stub columns under local compression
Mechanical behavior of circular and square concrete filled steel tube stub columns under local compression
复制标题
DOI:
10.1016/j.tws.2015.04.020
复制
发表时间:
2015-09-01
影响因子:
6.4
通讯作者:
Li, Da-wen
中科院分区:
文献类型:
--
作者:
Ding, Fa-xing;Liu, Jing;Li, Da-wen
This paper presents a combined experimental and numerical study on the behavior of both circular and square concrete-filled steel tube (CFT) stub columns under local compression. Twelve circular and eight square CFT stub columns were tested to study their bearing capacity and the key influential parameters. A 3D finite element model was established for simulation and parametric study to investigate the structural behavior of the stub columns. The numerical results agreed well with the experimental results. In addition, analytical formulas were proposed to calculate the load bearing capacity of CFT stub columns under local compression. (C) 2015 Elsevier Ltd. All rights reserved.