Proximal wear rates by tooth position of resin composite restorations.

Proximal wear rates by tooth position of resin composite restorations.
复制标题

树脂复合材料修复体不同牙齿位置的近端磨损率。

DOI:
10.1016/0300-5712(95)00040-2
复制
发表时间:
1996
影响因子:
4.4
通讯作者:
K. Leinfelder
K. Leinfelder
中科院分区:
医学2区
文献类型:
--
作者:
Stanley L. Wendt;T. Ziemiecki;K. Leinfelder

文献摘要

参考文献

被引文献

相似文献

本研究的目的是评估的preparations,以前放置在临床试验中,磨损率的近端表面,牙齿position.Materials和methodsSeventy树脂复合preparations进行了评估,在双尖牙和磨牙。其中50例为直接置入性栓塞,20例为间接置入性栓塞。对35颗双尖牙和35颗磨牙的近端磨损率进行了评价。所有的牙釉质均与未修复的牙釉质近端表面相对。选择10个牙釉质-牙釉质近端表面作为对照。在基线时,接触被判定为视觉上闭合,并且使用薄的未上蜡的牙线。在基线和6个月、12个月和24个月后拍摄照片以制作模型。由两名独立的评价者在变焦立体显微镜下测量近端磨损,通过分度转移帽之间的空间损失来确定。一个参数方差分析,学生纽曼Keuls,和日志曲线fittingtodata.ResultsWhen所有数据汇总,无论材料,有没有显着差异(P < 0.05)磨损值为第一和第二双尖牙和第一和第二磨牙。磨损率显示出高度的相关性(对数曲线拟合R2> 0.950),无论实际量的wear. ConclusionsIndependentof复合材料检查,有没有差异,在近端磨损量方面的牙齿在弓的位置。
ObjectiveThe purpose of this study was to evaluate restorations, previously placed in clinical trials, for the rate of wear of the proximal surfaces, by tooth position.Materials and methodsSeventy resin composite restorations were evaluated in bicuspids and molars. Fifty restorations were direct placement restorations and 20 were indirect placement restorations. Thirty-five bicuspids and 35 molars were evaluated for proximal wear rate. All restorations were opposing unrestored enamel proximal surfaces. Ten enamel to enamel proximal surfaces were chosen as controls. At baseline, contacts were judged to be closed visually and with thin, unwaxed dental floss. Impressions were taken at baseline and after 6, 12 and 24 months for the fabrication of models. Measurements for proximal wear, as determined by a loss of space between indexed transfer copings, were made under a zoom stereomicroscope by two independent evaluators. A parametric ANOVA, Student-Newman-Keuls, and log curve fit were applied to the data.ResultsWhen all data were pooled regardless of material, there were no significant differences (P < 0.05) in wear values for 1st and 2nd bicuspids and 1st and 2nd molars. Wear rates showed a high correlation (log curve fit R2> 0.950) regardless of actual amount of wear.ConclusionsRegardless of composites examined, there were no differences in the amount of proximal wear with regard to tooth position in the arch.
汇集后复合材料的长期临床磨损数据。
DOI: --
发表时间: 1994
影响因子: 1.4
作者:
Taylor,DF;Bayne,SC;Leinfelder,KF;Davis,S;Koch,GG
通讯作者: Koch,GG
DOI: 10.1016/0109-5641(92)90105-l
发表时间: 1992-09-01
期刊: DENTAL MATERIALS
影响因子: 5
作者:
BAYNE, SC;TAYLOR, DF;HEYMANN, HO
通讯作者: HEYMANN, HO
两种光固化后复合树脂的三年研究。
DOI: 10.1016/s0109-5641(86)80039-2
发表时间: 1986
期刊: Dental materials : official publication of the Academy of Dental Materials
影响因子: --
作者:
Sturdevant,JR;Lundeen,TF;SluderJr,TB;Leinfelder,KF
通讯作者: Leinfelder,KF