Quantitation of tamoxifen, 4-hydroxytamoxifen, and N- desmethyltamoxifen in human plasma by high performance liquid chromatography
Quantitation of tamoxifen, 4-hydroxytamoxifen, and N- desmethyltamoxifen in human plasma by high performance liquid chromatography
复制标题
高效液相色谱法定量人血浆中他莫昔芬、4-羟基他莫昔芬和 N-去甲基他莫昔芬
DOI:
--
复制
发表时间:
1985
期刊:
影响因子:
--
通讯作者:
M. Degregorio
中科院分区:
文献类型:
--
作者:
B. Wilbur;C. Benz;M. Degregorio
Abstract A reverse phase high performance liquid chromatography assay used for quantitative analysis of tamoxifen, 4-hydroxytamoxifen, and N-desmethyltamoxifen extracted from human plasma was developed. Plasma samples were spiked with an internal standard, nafoxidine, extracted with 2% butanol in hexane, and activated to fluorescence by exposure to high intensity short-wave ultraviolet (254 nm) light. Aliquots of extracted plasma were then injected onto a C18 reverse phase column and eluted isocratically with a mobile phase of water and triethylamine in methanol. Fluorescence of activated tamoxifen and its metabolites was measured at 266 nm. Peak height ratios were used to quantitate tamoxifen and its metabolites from extracted human plasma specimens.