VISUAL CAPACITY IN HEMIANOPIC FIELD FOLLOWING A RESTRICTED OCCIPITAL ABLATION
VISUAL CAPACITY IN HEMIANOPIC FIELD FOLLOWING A RESTRICTED OCCIPITAL ABLATION
复制标题
DOI:
10.1093/brain/97.1.709
复制
发表时间:
1974-01-01
期刊:
影响因子:
14.5
通讯作者:
MARSHALL, J
中科院分区:
文献类型:
--
作者:
WEISKRANTZ, L;WARRINGTON, EK;MARSHALL, J
METHODS AND RESULTSThe experimental procedures were carried out over two five-day periods, two to eight months post-operatively, when clinical examinations were also conducted. DB was never given knowledge of results during the course of any experiment. With the exception of the eye fixation experiment, which was carried out in a windowless room, all experiments were carried out in an office or a corridor in which it was not possible to control the level of background lighting completely. But in these cases the conditions were as dim as Venetian blinds made possible, and generally were only just bright enough for the testers to record the results. All tests were done binocularly. Experiment 1 was conducted two months post-operatively, and all other experiments eight months post-operatively.