A gas ultrasonic flowmeter for low pressure applications

A gas ultrasonic flowmeter for low pressure applications
复制标题

DOI:
10.1109/i2mtc.2017.7969954
复制
发表时间:
2017-05
期刊:
2017 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)
影响因子:
--
通讯作者:
Weiguo Zhao;Jieyong Yu;Shengyi Zhang;Chaochuan Huang;Jing-Wei Lin
Weiguo Zhao;Jieyong Yu;Shengyi Zhang;Chaochuan Huang;Jing-Wei Lin
中科院分区:
其他
文献类型:
--
作者:
Weiguo Zhao;Jieyong Yu;Shengyi Zhang;Chaochuan Huang;Jing-Wei Lin

文献摘要

被引文献

相似文献

Compared to high pressure gas medium, the signal attenuation in low pressure gas is more serious with low Signal Noise Rate. So the gas flow measurement is more difficult. In order to solve the problem, a ultrasonic gas flow meter with transit time method is presented. The flow measurement model has been derived to reduce the affection of temperature and pressure on ultrasonic sensors and circuits. The method of multipulse driving and digital Automatic Gain Circuit (AGC) are proposed to obtain stable echo waves. The comparator circuit is designed and a noise filtering method is designed to stabilize the transit time measurement result. The time measurement circuit adopts chip TDC-GP22 and the microchip adopts MSP430F448. Finally, the gas flow meter is tested in the standard device. The experimental results show that the accuracy class is 1.5 level and the turndown ratio is 60:1.