Effects of printing conditions on cell distribution within microspheres during inkjet-based bioprinting
Effects of printing conditions on cell distribution within microspheres during inkjet-based bioprinting
复制标题
DOI:
10.1063/1.5116371
复制
发表时间:
2019-09
期刊:
影响因子:
1.6
通讯作者:
Heqi Xu;Jazzmin Casillas;Changxue Xu
中科院分区:
文献类型:
--
作者:
Heqi Xu;Jazzmin Casillas;Changxue Xu
Inkjet-based bioprinting have been widely employed in a variety of applications in tissue engineering and drug screening and delivery. The typical bioink used in inkjet bioprinting consists of biological materials and living cells. During inkjet bioprinting, the cell-laden bioink is ejected out from the inkjet dispenser to form microspheres with cells encapsulated. The cell distribution within microspheres is defined as the distribution of cell number within the microspheres. The paper focuses on the effects of polymer concentration, excitation voltage, and cell concentration on the cell distribution within microspheres during inkjet printing of cell-laden bioink. The normal distribution has been utilized to fit the experimental results to obtain the mean and standard deviation of the distribution. It is found that the cell distribution within the microspheres increases with the increase of the cell concentration, sodium alginate concentration, and the excitation voltage.