Experimental study for 15-20 mA dc H- multicusp source.

Experimental study for 15-20 mA dc H- multicusp source.
复制标题

DOI:
10.1063/1.3266148
复制
发表时间:
2010-02
期刊:
The Review of scientific instruments
影响因子:
--
通讯作者:
Tianjue Zhang;X. Jia;Yinlong Lv;Jian Zou;F. Guan;Longcheng Wu;Gaofeng Pan;Gengshou Liu;Jun Lin;Tao Ge;H. Yao;Zhenhui Wang;S. An
Tianjue Zhang;X. Jia;Yinlong Lv;Jian Zou;F. Guan;Longcheng Wu;Gaofeng Pan;Gengshou Liu;Jun Lin;Tao Ge;H. Yao;Zhenhui Wang;S. An
中科院分区:
其他
文献类型:
--
作者:
Tianjue Zhang;X. Jia;Yinlong Lv;Jian Zou;F. Guan;Longcheng Wu;Gaofeng Pan;Gengshou Liu;Jun Lin;Tao Ge;H. Yao;Zhenhui Wang;S. An

文献摘要

被引文献

相似文献

Recently, a new H- source and test stand was developed at CIAE. The design of this new source is based on the experience on our previous 10-15 mA H(-) ion source and the source at TRIUMF. Major efforts include the study of the virtual filter magnetic field, confining magnetic field, filament shape and location, the vacuum improvement on the extracting area, the extraction optics, new control and interlock system of the power supplies. More than 15 mA of H-beam was obtained for 36 h with stability of +/-0.5%. The normalized emittance of 0.48pi mm mrad (4 rms normalized emittance) were measured with approximately 8 mA dc beam. Further experimental studies are proceeding in an effort to reach 20 mA with reasonable emittance at this moment. More study plans are conducted, e.g., building a longer source body and using cesium injection to get better emittance, which will be presented as a separate paper at this conference.