Study on heat transfer performance of metro tunnel capillary heat exchanger
Study on heat transfer performance of metro tunnel capillary heat exchanger
复制标题
DOI:
10.1016/j.scs.2018.11.016
复制
发表时间:
2019-02
影响因子:
11.7
通讯作者:
Li Tong;Huang Songtao;L. Shan;Yimei Wang
中科院分区:
文献类型:
--
作者:
Li Tong;Huang Songtao;L. Shan;Yimei Wang
The metro tunnel capillary heat exchanger, which is to lay the capillary along the wall surface of the subway tunnel, is a kind of front end heat exchanger of the air conditioning heat pump system. The numerical simulation is used to analyze the heat transfer characteristics of the metro tunnel capillary heat exchanger with different pipe spacings. Combined with the system regulation and operation, the optimal pipe spacing suitable for the metro tunnel capillary heat exchanger was obtained. Through experimental tests, we concluded the law of temperature distribution and the heat transfer characteristics of the sand with the capillary heat exchanger were buried, the correctness of the simulated value was verified.