Effect of high myopia on glaucoma diagnostic parameters measured with optical coherence tomography
Effect of high myopia on glaucoma diagnostic parameters measured with optical coherence tomography
复制标题
DOI:
10.1111/ceo.12318
复制
发表时间:
2014-11-01
影响因子:
4
通讯作者:
Goldberg, Ivan
中科院分区:
文献类型:
--
作者:
Kita, Yoshiyuki;Kita, Ritsuko;Goldberg, Ivan
BackgroundWe examined the influence of high myopia on conventional spectral-domain optical coherence tomographic parameters and assessed the macular ganglion cell complex thickness to macular outer retinal thickness ratio as a new optical coherence tomography parameter.DesignProspective cross-sectional study.ParticipantsSixty normal and 30 highly myopic eyes (refractive error more than -6 D).MethodsWe used the RTVue-100 to measure macular ganglion cell complex and circumpapillary retinal nerve fibre layer thickness, global loss volume, and focal loss volume and then calculated the ganglion cell complex thickness to macular outer retinal thickness ratio.Main Outcome MeasuresEach parameter was compared between the two groups. Using the area under receiver operating characteristics curve, the classification abilities of optical coherence tomography parameters were examined in highly myopic eyes.ResultsBetween normal and highly myopic eyes, we found significant differences in ganglion cell complex and retinal nerve fibre layer thickness, global loss volume and focal loss volume. The new ratio parameter was not significantly different between groups (55.74% vs. 54.50%). The area under receiver operating characteristics curve was 0.775 (P