AIJ guidelines for practical applications of CFD to pedestrian wind environment around buildings
AIJ guidelines for practical applications of CFD to pedestrian wind environment around buildings
复制标题
DOI:
10.1016/j.jweia.2008.02.058
复制
发表时间:
2008-10-01
影响因子:
4.8
通讯作者:
Shirasawa, Taichi
中科院分区:
文献类型:
--
作者:
Tominaga, Yoshihide;Mochida, Akashi;Shirasawa, Taichi
Significant improvements of computer facilities and computational fluid dynamics (CFD) software in recent years have enabled prediction and assessment of the pedestrian wind environment around buildings in the design stage. Therefore, guidelines are required that summarize important points in using the CFD technique for this purpose. This paper describes guidelines proposed by the Working Group of the Architectural Institute of Japan (AIJ). The feature of these guidelines is that they are based on cross-comparison between CFD predictions, wind tunnel test results and field measurements for seven test cases used to investigate the influence of many kinds of computational conditions for various flow fields. (c) 2008 Elsevier Ltd. All rights reserved.