En-face OCT imaging of the anterior chamber

En-face OCT imaging of the anterior chamber
复制标题

前房的 En-face OCT 成像

DOI:
10.1117/12.470490
复制
发表时间:
2002
影响因子:
3.4
通讯作者:
D. Jackson
D. Jackson
中科院分区:
医学2区
文献类型:
--
作者:
A. Podoleanu;J. Rogers;G. Dobre;R. Cucu;D. Jackson

文献摘要

被引文献

相似文献

我们报告一个系统能够收集对面OCT和共焦图像从前房。从角膜顶部测量的前房深度达7 mm处收集成对的此类图像。波长为85微米,功率为0.3mW。该系统提供:(i)多功能性,能够显示两种C扫描OCT图像(恒定深度,垂直于光轴)以及B扫描OCT图像(ii)使用共焦通道中的浦肯野反射的眼睛对准;(iii)在共焦图像上的总体眼睛引导;(iv)使用共焦图像对通过正面成像生成的B扫描图像中的正面移动进行校正。这种图像对的动画展示了该系统用于眼前节的体内成像的实用性。
We report a system capable of collecting pairs of en-face OCT and confocal images from the anterior chamber. Pairs of such images are collected from up to 7 mm deep in the anterior chamber measured from the top of the cornea. The wavelength is 85micrometers and the power 0.3 mW. The system offers: (i) versatility, being capable of displaying both C-scan OCT images (constant depth, oriented perpendicularly on the optic axis) as well as B-scan OCT images (containing the optic axis or longitudinal); (ii) eye alignment using the Purkinje reflections in the confocal channel; (iii) overall eye guidance, on the confocal image; (iv) correction for the en-face movement in the B-scan images generated by en-face imaging using the confocal image. Animations of such pairs of images demonstrate the utility of the system for in vivo imaging of the anterior segment of the eye.