Quantitative assessment of the supraspinatus tendon on MRI using T2/T2*mapping and shear-wave ultrasound elastography: a pilot study

Quantitative assessment of the supraspinatus tendon on MRI using T2/T2*mapping and shear-wave ultrasound elastography: a pilot study
复制标题

DOI:
10.1007/s00256-016-2534-0
复制
发表时间:
2017-02-01
期刊:
影响因子:
2.1
通讯作者:
Gyftopoulos, Soterios
Gyftopoulos, Soterios
中科院分区:
医学4区
文献类型:
--
作者:
Krepkin, Konstantin;Bruno, Mary;Gyftopoulos, Soterios

文献摘要

被引文献

相似文献

目的 确定 T2/T2* 映射与剪切波超声弹性成像 (SWE) 评估的冈上肌腱机械性能之间是否存在关联。材料和方法 这项符合 HIPAA 的前瞻性试点研究获得了我院机构审查委员会的批准。 8 名患者(3 名男性/5 名女性;年龄范围 44-72 岁)和 9 名肩膀接受了传统肩部 MRI、3-T 扫描仪上的 T2/T2* 映射和 SWE。两名肌肉骨骼放射科医生一致审查了 MRI 检查,以寻找冈上肌腱病理学的证据,并测量了全层撕裂的撕裂尺寸。 T2/T2* 值和超声剪切波速度 (SWV) 是在冈上肌腱插入 1-2 cm 内(内侧、中间、外侧)的三个相应等距感兴趣区域 (ROI) 中计算的。计算 T2/T2* 值与 SWV 之间以及 T2、T2*、SWV 和撕裂尺寸之间的 Pearson 相关系数。 结果 在横向 ROI(r = -0.86,p = 0.013)和总体平均 ROI(r = -0.90,p = 0.006)中,T2* 和 SWV 之间存在显着负相关。 T2 与横向和平均 ROI 中撕裂尺寸的测量值之间存在显着正相关(r 范围 0.71-0.77,p 范围 0.016-0.034)。中间和平均 ROI 的 SWV 和撕裂大小之间存在显着的负相关性(r 范围 -0.79-0.68,p 范围 0.011-0.046)。 结论 我们的初步研究证明了冈上肌腱中 T2* 值和剪切波速度值之间的潜在关系,这一发现可能导致对肩袖肌腱的改进、更定量的评估。
Objective To determine whether there is an association between T2/T2* mapping and supraspinatus tendon mechanical properties as assessed by shear-wave ultrasound elastography (SWE).Materials and methods This HIPAA-compliant prospective pilot study received approval from our hospital's institutional review board. Eight patients (3 males/5 females; age range 44-72 years) and nine shoulders underwent conventional shoulder MRI, T2/T2* mapping on a 3-T scanner, and SWE. Two musculoskeletal radiologists reviewed the MRI examinations in consensus for evidence of supraspinatus tendon pathology, with tear size measured for full-thickness tears. T2/T2* values and ultrasound shear-wave velocities (SWV) were calculated in three corresponding equidistant regions of interest (ROIs) within the insertional 1-2 cm of the supraspinatus tendon (medial, middle, lateral). Pearson correlation coefficients between T2/T2* values and SWV, as well as among T2, T2*, SWV and tear size, were calculated.Results There was a significant negative correlation between T2* and SWV in the lateral ROI (r = -0.86, p = 0.013) and overall mean ROI (r = -0.90, p = 0.006). There was significant positive correlation between T2 and measures of tear size in the lateral and mean ROIs (r range 0.71-0.77, p range 0.016-0.034). There was significant negative correlation between SWV and tear size in the middle and mean ROIs (r range -0.79-0.68, p range 0.011-0.046).Conclusion Our pilot study demonstrated a potential relationship between T2* values and shear wave velocity values in the supraspinatus tendon, a finding that could lead to an improved, more quantitative evaluation of the rotator cuff tendons.