Non-linear ultrasonic technique to assess fatigue damage in structural steel
Non-linear ultrasonic technique to assess fatigue damage in structural steel
复制标题
DOI:
10.1016/j.scriptamat.2006.03.037
复制
发表时间:
2006-07
影响因子:
6
通讯作者:
S. P. Sagar;Das Saumya;N. Parida;D. Bhattacharya
中科院分区:
文献类型:
--
作者:
S. P. Sagar;Das Saumya;N. Parida;D. Bhattacharya
A non-linear ultrasonic technique has been used to assess the fatigue damage in low carbon structural steel. The percentage of total harmonic distortion, which is the ratio of the amplitude of 2nd harmonic and the fundamental, has been introduced as the measurement parameter in this paper. It has also been observed that before crack initiation the 2nd harmonic amplitude is comparable to the fundamental. The results have been analysed in light of the dislocation theory for harmonic generation during material degradation.