Model-based control of cardiac alternans in Purkinje fibers
Model-based control of cardiac alternans in Purkinje fibers
复制标题
DOI:
10.1103/physreve.84.041927
复制
发表时间:
2011-10-21
影响因子:
2.4
通讯作者:
Fenton, Flavio H.
中科院分区:
文献类型:
--
作者:
Garzon, Alejandro;Grigoriev, Roman O.;Fenton, Flavio H.
This paper describes a systematic approach to suppressing cardiac alternans in simulated Purkinje fibers using localized current injections. We investigate the controllability and observability of the periodically paced Noble model for different locations of the recording and control electrodes. In particular, we show that the loss of controllability causes the failure of the control approach introduced by Echebarria and Karma [Chaos 12, 923 (2002)] for longer fiber lengths. Furthermore, we explain how the optimal locations for the recording and control electrodes and the timing of the feedback current can be selected, accounting for both linear and nonlinear effects, effectively doubling the length of fibers that can be controlled with previous methods.