A compensated multi-gap RPC with 2 m strips for the LEPS2 experiment
A compensated multi-gap RPC with 2 m strips for the LEPS2 experiment
复制标题
用于 LEPS2 实验的带 2 m 条带的补偿多间隙 RPC
DOI:
10.1016/j.nima.2019.02.014
复制
发表时间:
2019
期刊:
影响因子:
--
通讯作者:
Yosoi M.
中科院分区:
文献类型:
--
作者:
Watanabe K.;Tanaka S.;Chang W.C.;Chen H.;Chu M.L.;Cuenca-Garcia J.J.;Gogami T.;Gonzalez-Diaz D.;Niiyama M.;Ohashi Y.;Ohnishi H.;Tomida N.;Yosoi M.
We have developed multi-gap resistive plate chambers (MRPCs) with 2.5 x 200 cm2 readout strips for the time-of-flight (TOF) detector system of the LEPS2 experiment at SPring-8. These chambers consist of 2 stacks and 5 gas gaps per stack, in a mirrored configuration. A time resolution of sigma ~ 80 ps was achieved for any position within a strip (at above 99% detection efficiency); after performing the time-charge slewing correction, this value could be reduced to 60 ps. A link between the small contribution of the slewing correction to timing and the suppression of modal dispersion in the detector could be established.