Comparison of laparoscopic skills performance between single-site access (SSA) devices and an independent-port SSA approach.
Comparison of laparoscopic skills performance between single-site access (SSA) devices and an independent-port SSA approach.
复制标题
DOI:
10.1007/s00464-011-1941-5
复制
发表时间:
2012-03
影响因子:
3.1
通讯作者:
Brunt, L. Michael
中科院分区:
文献类型:
--
作者:
Schill, Matthew R.;Varela, J. Esteban;Frisella, Margaret M.;Brunt, L. Michael
We compared performance of validated laparoscopic tasks on four commercially available single site access (SSA) access devices (AD) versus an independent port (IP) SSA set-up. A prospective, randomized comparison of laparoscopic skills performance on four AD (GelPOINT™, SILS™ Port, SSL Access System™, TriPort™) and one IP SSA set-up was conducted. Eighteen medical students (2nd–4th year), four surgical residents, and five attending surgeons were trained to proficiency in multi-port laparoscopy using four laparoscopic drills (peg transfer, bean drop, pattern cutting, extracorporeal suturing) in a laparoscopic trainer box. Drills were then performed in random order on each IP-SSA and AD-SSA set-up using straight laparoscopic instruments. Repetitions were timed and errors recorded. Data are mean ± SD, and statistical analysis was by two-way ANOVA with Tukey HSD post-hoc tests. Attending surgeons had significantly faster total task times than residents or students (p< 0.001), but the difference between residents and students was NS. Pair-wise comparisons revealed significantly faster total task times for the IP-SSA set-up compared to all four AD-SSA’s within the student group only (p<0.05). Total task times for residents and attending surgeons showed a similar profile, but the differences were NS. When data for the three groups was combined, the total task time was less for the IP-SSA set-up than for each of the four AD-SSA set-ups (p < 0.001). Similarly,, the IP-SSA set-up was significantly faster than 3 of 4 AD-SSA set-ups for peg transfer, 3 of 4 for pattern cutting, and 2 of 4 for suturing. No significant differences in error rates between IP-SSA and AD-SSA set-ups were detected. When compared to an IP-SSA laparoscopic set-up, single site access devices are associated with longer task performance times in a trainer box model, independent of level of training. Task performance was similar across different SSA devices.
登录
查看更多内容
DOI:
10.1007/s00464-009-0781-z
发表时间:
2010-06-01
影响因子:
3.1
作者:
Romanelli, John R.;Roshek, Thomas B., III;Earle, David B.
通讯作者:
Earle, David B.
DOI:
10.1007/s00464-009-0661-6
发表时间:
2010-03-01
影响因子:
3.1
作者:
Vidal, Oscar;Valentini, Mauro;Garcia-Valdecasas, Juan C.
通讯作者:
Garcia-Valdecasas, Juan C.
DOI:
10.1007/s00464-010-0940-2
发表时间:
2010-09-01
影响因子:
3.1
作者:
Targarona, Eduardo M.;Luis Pallares, Jose;Trias, Manuel
通讯作者:
Trias, Manuel
影响因子:
3
作者:
Marks, Jeffrey;Tacchino, Roberto;Shah, Sajani
通讯作者:
Shah, Sajani
DOI:
10.1016/j.jamcollsurg.2010.10.009
发表时间:
2011-03-01
影响因子:
5.2
作者:
Rieder, Erwin;Martinec, Danny V.;Swanstrom, Lee L.
通讯作者:
Swanstrom, Lee L.