Effect of astigmatism on visual acuity in eyes with a diffractive multifocal intraocular lens

Effect of astigmatism on visual acuity in eyes with a diffractive multifocal intraocular lens
复制标题

DOI:
10.1016/j.jcrs.2010.02.016
复制
发表时间:
2010-08-01
影响因子:
2.8
通讯作者:
Hayashi, Hideyuki
Hayashi, Hideyuki
中科院分区:
医学2区
文献类型:
--
作者:
Hayashi, Ken;Manabe, Shin-ichi;Hayashi, Hideyuki

文献摘要

被引文献

相似文献

目得:目的:研究散光对植入衍射型多焦点人工透镜(IOL)的眼在不同距离下视力的影响。在本研究中,眼睛植入了+3.00屈光度(D)增加(add)的衍射多焦点IOL 00 D增加的衍射多焦点IOL(AcrySof ReSTOR SN 6AD 3)或单焦点IOL(AcrySof SN 60 WF)。通过添加不同屈光度(0.00,0.50,1.00,1.50,2.00)的柱面透镜来模拟散光,之后在不同距离处测量远距离矫正视力。在散光为0.00 D和0.50 D时,+4.00 D组的远矫正近视力(DCNVA)和+3.00 D组的远矫正中视力(DCIVA)和DCNVA显著优于单焦点组;矫正远视力(CDVA)相似。在2个多焦点组中,散光为1.00 D的DCNVA更好;然而,在散光为1.50 D和2.00 D的情况下,多焦点组中0.5 m处的CDVA和DCIVA显著差于单焦点组,尽管DCNVA相似。当散光大于1.00D时,多焦点组的平均CDVA和DCNVA达到有用水平(20/40)。结论:衍射型多焦点人工晶状体眼的散光损害了所有远视力,表明需要矫正大于1.00D的散光。
PURPOSE: To examine the effect of astigmatism on visual acuity at various distances in eyes with a diffractive multifocal intraocular lens (IOL).SETTING: Hayashi Eye Hospital, Fukuoka, Japan.METHODS: In this study, eyes had implantation of a diffractive multifocal IOL with a +3.00 diopter (D) addition (add) (AcrySof ReSTOR SN6AD1), a diffractive multifocal IOL with a +4.00 D add (AcrySof ReSTOR SN6AD3), or a monofocal IOL (AcrySof SN60WF). Astigmatism was simulated by adding cylindrical lenses of various diopters (0.00, 0.50, 1.00, 1.50, 2.00), after which distance-corrected acuity was measured at various distances.RESULTS: At most distances, the mean visual acuity in the multifocal IOL groups decreased in proportion to the added astigmatism. With astigmatism of 0.00 D and 0.50 D, distance-corrected near visual acuity (DCNVA) in the +4.00 D group and distance-corrected intermediate visual acuity (DCIVA) and DCNVA in the +3.00 D group were significantly better than in the monofocal group; the corrected distance visual acuity (CDVA) was similar. The DCNVA with astigmatism of 1.00 D was better in 2 multifocal groups; however, with astigmatism of 1.50 D and 2.00 D, the CDVA and DCIVA at 0.5m in the multifocal groups were significantly worse than in the monofocal group, although the DCNVA was similar. With astigmatism of 1.00 D or greater, the mean CDVA and DCNVA in the multifocal groups reached useful levels (20/40).CONCLUSION: The presence of astigmatism in eyes with a diffractive multifocal IOL compromised all distance visual acuities, suggesting the need to correct astigmatism of greater than 1.00 D.