GAS CLEANING WITH SEMI-WET TYPE PLASMA REACTOR
GAS CLEANING WITH SEMI-WET TYPE PLASMA REACTOR
复制标题
DOI:
10.1109/28.382109
复制
发表时间:
1995-05-01
影响因子:
4.4
通讯作者:
FURUTA, S
中科院分区:
文献类型:
--
作者:
CHAKRABARTI, A;MIZUNO, A;FURUTA, S
An experimental study on the removal of NH3, NO, NOx in concentration of 10-40 ppm in air has been carried out using plasma chemical reactions in a streamer corona discharge, The results of the performance of dry type and semi-wet type reactors are compared, The effects of different type of applied voltages such as rectangular pulse, 60-Hz sinusoidal and 18-kHz alternating voltages are investigated, During NO removal, O-3 and NO2 are produced, NO2 can, partially, be removed with higher power input into the discharge. Another undesirable pollutant, namely N2O, is also produced, especially, in case of dry reactors having long residence time (similar to 2.4 s), N2O production decreases, essentially, to zero at 0.6-s residence time while using a semi-wet reactor, In general, higher removal efficiency has been obtained with pulse voltage in a semi-wet reactor, NH3 in air appears to produce ozone and ammonium nitrate in a discharge, The performance of semi-wet reactors on the removal of submicron dust particles has also been investigated and very high removal efficiency (similar to 93% at 0.6-s residence time) has been obtained.