Emissivity range constraints algorithm for multi-wavelength pyrometer (MWP).
Emissivity range constraints algorithm for multi-wavelength pyrometer (MWP).
复制标题
DOI:
10.1364/oe.24.019185
复制
发表时间:
2016-08
期刊:
影响因子:
3.8
通讯作者:
Jian Xing;R. S. Rana;Weihong Gu
中科院分区:
文献类型:
--
作者:
Jian Xing;R. S. Rana;Weihong Gu
In order to realize rapid and real temperature measurement for high temperature targets by multi-wavelength pyrometer (MWP), emissivity range constraints to optimize data processing algorithm without effect from emissivity has been developed. Through exploring the relation between emissivity deviation and true temperature by fitting of large number of data from different emissivity distribution target models, the effective search range of emissivity for every time iteration is obtained, so data processing time is greatly reduced. Simulation and experimental results indicate that calculation time is less by 0.2 seconds with 25K absolute error at 1800K true temperature, and the efficiency is improved by more than 90% compared with the previous algorithm. The method has advantages of simplicity, rapidity, and suitability for in-line high temperature measurement.