Neoclassical transport in the CHS device and its outlook for improvement
Neoclassical transport in the CHS device and its outlook for improvement
复制标题
CHS装置中的新古典传输及其改进前景
DOI:
10.1088/0741-3335/43/10/303
复制
发表时间:
2001
期刊:
影响因子:
--
通讯作者:
O. S. Pavlichenko
中科院分区:
文献类型:
--
作者:
M. Heyn;M. Isobe;S. Kasilov;W. Kernbichler;K. Matsuoka;V. Nemov;S. Okamura;O. S. Pavlichenko
The 1/ν neoclassical transport is computed for the standard, the drift-orbit-optimized and the quasi-axisymmetric versions of CHS. For the computations, a new method is used which is based on the integration along magnetic field lines. The calculations show the advantage of the quasi-axisymmetric CHS configuration over the standard configuration resulting in a reduced 1/ν transport. It is shown that also for the drift-orbit-optimized configuration the 1/ν transport is reduced; however, by a smaller amount than for the quasi-axisymmetric configuration.
DOI:
--
发表时间:
--
期刊:
影响因子:
--
作者:
通讯作者:
--
DOI:
--
发表时间:
2006
期刊:
Journal of the Korean Physical Society 49
影响因子:
--
作者:
S.Okamura;et. al.
通讯作者:
et. al.