CFD analyses for passive house with Trombe wall and impact to energy demand
CFD analyses for passive house with Trombe wall and impact to energy demand
复制标题
DOI:
10.1016/j.enbuild.2014.11.018
复制
发表时间:
2015-07-01
影响因子:
6.7
通讯作者:
Svorcan, Jelena
中科院分区:
文献类型:
--
作者:
Bajc, Tamara;Todorovic, Maja N.;Svorcan, Jelena
The paper deals with a comprehensive, three-dimensional numerical CFD analysis of temperature fields in Trombe wall and in the adjacent room for several days of a typical meteorological year (TMY) for a moderate continental climate. Construction of the Trombe wall is optimized, using different types of glassing on the outside of the wall. For summer day, the glass is considered to be covered with PV stripes during the daylight in order to prevent overheating. The central concrete core of the wall is covered with a layer of dark paint, on the outside, to improve absorptivity of the wall. The Trombe wall is oriented on south side of the house, and designed with openings with flaps in concrete core. Those openings are simulated in opened and closed positions. The U-values of the house envelope are considered according to passive house standards. Temperature fields in concrete core and in the room with Trombe wall are simulated, as well as velocity fields. According to these results, analysis of energy savings potential is performed. (C) 2014 Elsevier B.V. All rights reserved.