In-Situ Fuel Concentration Measurement Near Spark Plug by 3.392 μm Infrared Absorption Method-Application to Spark Ignition Engine
In-Situ Fuel Concentration Measurement Near Spark Plug by 3.392 μm Infrared Absorption Method-Application to Spark Ignition Engine
复制标题
3.392μm红外吸收法现场测量火花塞附近燃油浓度——在火花点火发动机中的应用
DOI:
10.4271/2003-01-1109
复制
发表时间:
2003
期刊:
影响因子:
--
通讯作者:
E. Tomita
中科院分区:
文献类型:
--
作者:
A. Nishiyama;N. Kawahara;E. Tomita
This study measured the fuel concentration near a spark plug using a laser infrared absorption method. An IR spark plug sensor with a double-pass measurement length was developed. A He-Ne laser with a wavelength of 3.392 μm, which coincides with the absorption line of hydrocarbons, was used as the light source. In order to confirm the measurement accuracy, the concentrations of a methane-air mixture were measured in a compression-expansion engine. Then, the IR spark plug sensor was used for measurements in a 4-stroke spark-ignition engine fuelled with isooctane. The air/fuel ratio measured using this system clearly agreed with the mean air/fuel ratio.