Determination of thoron equilibrium factor from simultaneous long-term thoron and its progeny measurements

Determination of thoron equilibrium factor from simultaneous long-term thoron and its progeny measurements
复制标题

DOI:
10.1093/rpd/ncr228
复制
发表时间:
2012-04-01
影响因子:
1
通讯作者:
Tokonami, Shinji
Tokonami, Shinji
中科院分区:
环境科学与生态学4区
文献类型:
--
作者:
Chen, Jing;Moir, Deborah;Tokonami, Shinji

文献摘要

被引文献

相似文献

用3个月的同时测量的109个家庭的最低层的钍射气及其子体浓度,钍射气平衡因子的几何平均数(GM)被确定为0.019的几何标准差(GSD)为3.63。结合对138户居民的研究结果,确定了钍射气平衡因子的GM为0.022,GSD为3.02。结果表明,联合国气候变化委员会推荐的钍射气F值为0.02,对加拿大受测家庭是合理的。
With 3-month simultaneous measurements of thoron and its progeny concentrations in the lowest floors of 109 homes, the geometric mean (GM) of thoron equilibrium factor was determined to be 0.019 with a geometric standard deviation (GSD) of 3.63. Combined with the analysis from results obtained from a previous study in 138 homes, the GM of thoron equilibrium factor was determined to be 0.022 with a GSD of 3.02. The results indicate that the F value of 0.02 for thoron recommended by UNSCEAR is a reasonable value for those Canadian homes tested.