Transmission electron microscope study of a threading dislocation with b=[0001]+<1-100> and its effect on leakage in a 4H-SiC MOSFET

Transmission electron microscope study of a threading dislocation with b=[0001]+<1-100> and its effect on leakage in a 4H-SiC MOSFET
复制标题

b=[0001] <1-100> 的穿透位错的透射电子显微镜研究及其对 4H-SiC MOSFET 泄漏的影响

DOI:
10.1080/09500839.2013.798047
复制
发表时间:
2013
影响因子:
1.2
通讯作者:
Hiroyasu
Hiroyasu
中科院分区:
材料科学4区
文献类型:
--
作者:
Onda;Shoichi; Watanabe;Hiroki; Kito;Yasuo; Kondo;Hiroyuki; Uehigashi;Hideyuki; Hosokawa;Norikazu; Hisada;Yoshiyuki; Shiraishi;Kenji; Saka;Hiroyasu

文献摘要

相似文献

用透射电子显微镜研究了4H-SiCMOSFET中的穿线位错(TD‘s),着重分析了它们对p-n结漏电流的影响。共发现了两种位错类型:一种为螺纹型位错(TnSD),另一种为螺纹型混合位错(TMD),后者在本研究中为首次发现。TnSD只显示了可以忽略的小泄漏,而TMD显示了很大的泄漏。对渗漏程度不同的原因进行了讨论。
Threading dislocations (TD’s) in a 4H-SiC MOSFET were characterized using transmission electron microscopy with special emphasis of their effects on leakage in a p–n junction. Two types of TD’s were identified; a threading near-screw dislocation (TnSD) with , and a threading mixed dislocation (TMD) with , the last of which has been found for the first time in this study. The TnSD show only negligibly small leakage, while TMD shows a large leakage. Origins of the difference in the degree of the leakage have been discussed.