Patellofemoral complications after posterior-stabilized total knee arthroplasty - A comparison of 2 different implant designs

Patellofemoral complications after posterior-stabilized total knee arthroplasty - A comparison of 2 different implant designs
复制标题

DOI:
10.1054/arth.2002.32173
复制
发表时间:
2002-06-01
影响因子:
3.5
通讯作者:
Kieckbusch, T
Kieckbusch, T
中科院分区:
医学2区
文献类型:
--
作者:
Anderson, MJ;Becker, DL;Kieckbusch, T

文献摘要

被引文献

相似文献

We conducted a retrospective review of 2 consecutive series of posterior-stabilized total knee arthroplasties (TKAs) to evaluate patellofemoral complications, in particular, significant patellofemoral crepitance or patellar clunk syndrome. Twenty posterior-stabilized Axiom PSK (Wright Medical Technology, Arlington, TN) TKAs (group 1) were compared with 20 posterior cruciate-sacrificed Advance medial pivot (Wright Medical Technology, Arlington, TN) TKAs (group 2). The average age in group I was 69 years and in group 2 was 70 years. Preoperative valgus alignment in group I was 7.5degrees and in group 2 was 1.3degrees. Postoperative valgus alignment for the 2 groups was 4.8degrees and 5.3degrees valgus, Postoperative patellar tilt for the 2 groups was 0.9degrees lateral tilt and 8degrees lateral tilt. Patellofemoral signs of crepitance greater than or equal to2 + and significant box impingement complaints of either snapping or clunking decreased significantly postoperatively from 5 of 20 (25%) in group 1 to 0 of 20 in group 2 (P=.0079).