Wearable Cardioverter-Defibrillator after Myocardial Infarction.
Wearable Cardioverter-Defibrillator after Myocardial Infarction.
复制标题
DOI:
10.1056/nejmoa1800781
复制
发表时间:
2018-09-27
期刊:
影响因子:
--
通讯作者:
VEST Investigators
中科院分区:
文献类型:
--
作者:
Olgin JE;Pletcher MJ;Vittinghoff E;Wranicz J;Malik R;Morin DP;Zweibel S;Buxton AE;Elayi CS;Chung EH;Rashba E;Borggrefe M;Hue TF;Maguire C;Lin F;Simon JA;Hulley S;Lee BK;VEST Investigators
Despite the high rate of sudden death after myocardial infarction among patients with a low ejection fraction, implantable cardioverter-defibrillators are contraindi-cated until 40 to 90 days after myocardial infarction. Whether a wearable cardio- verter-defibrillator would reduce the incidence of sudden death during this high-risk period is unclear. We randomly assigned (in a 2:1 ratio) patients with acute myocardial infarction and an ejection fraction of 35% or less to receive a wearable cardioverter-defibrillator plus guideline-directed therapy (the device group) or to receive only guideline-directed therapy (the control group). The primary outcome was the composite of sudden death or death from ventricular tachyarrhythmia at 90 days (arrhythmic death). Secondary outcomes included death from any cause and nonarrhythmic death. Of 2302 participants, 1524 were randomly assigned to the device group and 778 to the control group. Participants in the device group wore the device for a median of 18.0 hours per day (interquartile range, 3.8 to 22.7). Arrhythmic death occurred in 1.6% of the participants in the device group and in 2.4% of those in the control group (relative risk, 0.67; 95% confidence interval [CI], 0.37 to 1.21; P=0.18). Death from any cause occurred in 3.1% of the participants in the device group and in 4.9% of those in the control group (relative risk, 0.64; 95% CI, 0.43 to 0.98; uncorrected P=0.04), and nonarrhythmic death in 1.4% and 2.2%, respectively (relative risk, 0.63; 95% CI, 0.33 to 1.19; uncorrected P=0.15). Of the 48 participants in the device group who died, 12 were wearing the device at the time of death. A total of 20 participants in the device group (1.3%) received an appropriate shock, and 9 (0.6%) received an inappropriate shock. Among patients with a recent myocardial infarction and an ejection fraction of 35% or less, the wearable cardioverter-defibrillator did not lead to a significantly lower rate of the primary outcome of arrhythmic death than control. (Funded by the National Institutes of Health and Zoll Medical; VEST ClinicalTrials.gov number, NCT01446965.)