Characterization of Emissions of Condensable Particulate Matter in Clinker Kilns Using a Dilution Sampling System
Characterization of Emissions of Condensable Particulate Matter in Clinker Kilns Using a Dilution Sampling System
复制标题
DOI:
10.1021/acs.energyfuels.7b00692
复制
发表时间:
2017-08
期刊:
影响因子:
5.3
通讯作者:
M. Cano;F. Vega;B. Navarrete;A. Plumed;J. A. Camino
中科院分区:
文献类型:
--
作者:
M. Cano;F. Vega;B. Navarrete;A. Plumed;J. A. Camino
Although significant steps have been taken over the last few decades in terms of creating policies aimed at controlling emissions, with the consequent toughening of the emission thresholds, the damage to air quality caused by particulate matter 2.5 μm or less in diameter particles currently represents a major worry on a global scale, mainly as a result of its involvement in significant harm to human health and the environment alike. Within this subgroup, the condensable particulate matter (CPM) produced in large combustion plants is susceptible to being a major contributor to the total mass of fine particles present in the air that we breathe. This work compiles the results obtained from CPM concentration measurements taken at the source of combustion gas emissions in an industrial clinker kiln, using an innovative sampling train developed at the University of Seville. In addition to this and applying adequate analytical techniques, we have characterized the nature of the CPM emitted at this facility and ...