Seismocardiography and 4D flow MRI reveal impact of aortic valve replacement on chest acceleration and aortic hemodynamics.
Seismocardiography and 4D flow MRI reveal impact of aortic valve replacement on chest acceleration and aortic hemodynamics.
复制标题
地震心动图和 4D 血流 MRI 揭示了主动脉瓣置换术对胸部加速度和主动脉血流动力学的影响。
DOI:
10.1111/jocs.14289
复制
发表时间:
2020
影响因子:
1.6
通讯作者:
Barker,AlexJ
中科院分区:
文献类型:
--
作者:
Johnson,EthanMI;Etemadi,Mozziyar;Malaisrie,SChris;McCarthy,PatrickM;Markl,Michael;Barker,AlexJ
Aortic valve replacement (AVR) is a common treatment for severe aortic valve disease, which can adversely affect blood flow in the aorta. Seismocardiography (SCG) measures physical vibrations at the exterior of the chest, which can be sensitive to altered cardiac function and flow dynamics. Magnetic resonance imaging (MRI) can image blood movement, and it can provide depiction and quantification of aortic flow. Here we present SCG and MRI measurements from before and after AVR and ascending aorta replacement, in the case of a woman with bicuspid aortic valve disease and a dilated ascending aorta. SCG measurements show elevated energy during systole indicating stenotic flow before surgery and lowered systolic energy levels after replacement with a prosthetic valve. MRI shows jetting, helical flow before surgery, and cohesive flow after.