Impaction Bone Grafting Combined with Titanium Mesh for Acetabular Bone Defects Reconstruction in Total Hip Arthroplasty Revision: A Retrospective and Mini-Review Study.
Impaction Bone Grafting Combined with Titanium Mesh for Acetabular Bone Defects Reconstruction in Total Hip Arthroplasty Revision: A Retrospective and Mini-Review Study.
复制标题
DOI:
10.1111/os.13262
复制
发表时间:
2022-05
影响因子:
2.1
通讯作者:
Sheng, Pu-yi
中科院分区:
文献类型:
--
作者:
Li, Xiang;Pan, Bai-qi;Wu, Xiao-yu;Fu, Ming;Liao, Wei-ming;Wu, Chu-heng;Sheng, Pu-yi
To investigate the application of impaction bone grafting (IBG) combined with Ti‐alloy mesh for acetabular bone defect reconstruction in total hip arthroplasty (THA) revision and follow up the clinical outcomes and imaging findings. The clinical and imaging data of patients who were admitted to our hospital from January 2000 to December 2020 and underwent acetabular bone defects reconstruction using IBG combined with titanium mesh were retrospectively analyzed. Preoperative and post‐revision Oxford and Harris scores, and post‐revision complications were evaluated. Radiographs were used to determine center of rotation (COR) of the hip joint, transparency line, bone graft fusion, and bone mineral density (BMD) around the hip joint. Significant improvement was observed in both Oxford and Harris scores (P < 0.05). The radiographs taken at the last follow‐up examination showed no significant differences in the acetabulum COR, offsets, inclination angle, mean ratio of vertical value, and BMD analysis between the post‐revision side and contralateral side (P > 0.05). The follow‐up data showed restoration of the mesh implant and graft bone fusion. The application of IBG combined with titanium‐alloy mesh in revision THA patients with acetabular defects was found to provide satisfactory outcomes. However, large‐scale studies are still needed to further elucidate the long‐term outcomes. We investigate the application of impaction bone grafting (IBG) combined with titanium mesh for acetabular bone defects reconstruction in revision total hip arthroplasty (THA), and follow up the clinical outcomes and imaging findings. Post‐revision radiographs show the measurement of horizontal/vertical value of the acetabular implant, acetabulum offsets in a hip.
登录
查看更多内容
影响因子:
4.2
作者:
Buttaro, Martin A.;Comba, Fernando;Piccaluga, Francisco
通讯作者:
Piccaluga, Francisco
DOI:
10.1097/01.blo.0000149822.49890.5e
发表时间:
2004-12-01
影响因子:
4.2
作者:
Gross, AE;Goodman, S
通讯作者:
Goodman, S
影响因子:
4.2
作者:
Garcia-Rey, Eduardo;Madero, Rosario;Garcia-Cimbrelo, Eduardo
通讯作者:
Garcia-Cimbrelo, Eduardo
影响因子:
2.3
作者:
Gruber MS;Jesenko M;Burghuber J;Hochreiter J;Ritschl P;Ortmaier R
通讯作者:
Ortmaier R
影响因子:
2.7
作者:
Amirouche, Farid;Solitro, Giovanni F.;Bobko, Aimee
通讯作者:
Bobko, Aimee