ESTIMATING OXYGEN-SATURATION OF BLOOD INVIVO WITH MR IMAGING AT 1.5T
ESTIMATING OXYGEN-SATURATION OF BLOOD INVIVO WITH MR IMAGING AT 1.5T
复制标题
DOI:
10.1002/jmri.1880010303
复制
发表时间:
1991-05-01
期刊:
影响因子:
--
通讯作者:
MACOVSKI, A
中科院分区:
文献类型:
--
作者:
WRIGHT, GA;HU, BS;MACOVSKI, A
The use of magnetic resonance (MR) imaging is investigated for noninvasively estimating the oxygen saturation of human blood (%HbO2) in vivo by means of relaxation characteristics identified in earlier MR spectrometry studies. To this end, a sequence is presented for determining the T2 of vascular blood in regions in which motions of the body and of the blood itself present a major challenge. With use of this sequence on a commercial 1.5-T whole-body imager, the relationship between the T2 and %HbO2 of blood is calibrated in vitro for the conditions expected in vivo. T2 varies predictably from about 30 to 250 msec as %HbO2 varies from 30% to 96%. T2 values measured in situ for vascular blood in the mediastinum of several healthy subjects qualitatively reflected the behavior observed in vitro. Estimates of % HbO2 for these vessels obtained with the in vitro calibration appear reasonable, particularly for venous blood, although difficulties arise in selecting the appropriate calibration factors. These encouraging initial results support a more systematic study of potential sources of error and an examination of the accuracy of in vivo measurements by comparison with direct measurements of % HbO2 in vessels.